Studying of Some Characteristics and parameters of Argon Glow discharge plasma Using Hollow Anode Diameter

Shamo Kh. Al-Hakary(1) , Esraa A. Mohammed Saeed(2) , Diyar A. Bleej(3) , Suzan M. Haji(4) , Sahme A. Hussain(5)
(1) University of Zakho ,
(2) University of Zakho ,
(3) University of Zakho ,
(4) University of Zakho ,
(5) Directorate of Douhk Education

Abstract

Hollow anode argon glow discharge plasma has been investigated experimentally at different argon gas pressure from constant discharge current. A sufficient high voltage has been applied among the electrodes to obtain breakdown. Firstly, we studied the influence of hollow anode diameter on the breakdown voltage and Paschens law. The inner diameters of hollow anodes used in our work were (10, 15, 20, 25, 30, 35, and 40) mm. Secondly under the same conditions we extended our study to measure some plasma parameters in the negative glow region using direct current argon glow discharge. The temperature and density of electrons in the negative glow were measured using double probes. From the (Ip-Vp) characteristics of double probes, we obtained plasma parameters by using computer MATLAB program. The results showed that the measured Pashence's curve closes to the well-known theoretical Pashence's law. The breakdown voltage and its minimum value decreased with increasing the hollow anode diameter. The Paschen’s curve became wide and shifted to lower pressure with increasing the diameter. The reduction area of hollow anode caused dens and luminous intensity of plasma to occur in the negative glow region. Increasing the diameter resulted in decreasing the temperature and density of electron.

Full text article

Generated from XML file

Authors

Shamo Kh. Al-Hakary
Shamo.awsi@uoz.edu.krd (Primary Contact)
Esraa A. Mohammed Saeed
Diyar A. Bleej
Suzan M. Haji
Sahme A. Hussain
Author Biographies

Shamo Kh. Al-Hakary

Department of Physics, Faculty of Science, University of Zakho, Kurdistan Region, Iraq.

Esraa A. Mohammed Saeed

Department of Physics, Faculty of Science, University of Zakho, Kurdistan Region, Iraq.

Diyar A. Bleej

Department of Physics, Faculty of Science, University of Zakho, Kurdistan Region, Iraq.

Suzan M. Haji

Department of Physics, Faculty of Science, University of Zakho, Kurdistan Region, Iraq.

Sahme A. Hussain

Department of Physics, Faculty of Science, University of Zakho, Kurdistan Region, Iraq.

Al-Hakary, S. K., Mohammed Saeed, E. A., Bleej, D. A., Haji, S. M., & Hussain, S. A. (2018). Studying of Some Characteristics and parameters of Argon Glow discharge plasma Using Hollow Anode Diameter. Science Journal of University of Zakho, 6(1), 26-31. https://doi.org/10.25271/2018.6.1.401

Article Details

How to Cite

Al-Hakary, S. K., Mohammed Saeed, E. A., Bleej, D. A., Haji, S. M., & Hussain, S. A. (2018). Studying of Some Characteristics and parameters of Argon Glow discharge plasma Using Hollow Anode Diameter. Science Journal of University of Zakho, 6(1), 26-31. https://doi.org/10.25271/2018.6.1.401

Similar Articles

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)

No Related Submission Found